Construction and Persistent-Mode Operation of $\hbox{MgB}_{2}$ Coils in the Range 10–15 K for a 0.5-T/240-mm Cold Bore MRI Magnet

2014 · IEEE Transactions on Applied Superconductivity

저자

Jiayin Ling, John P. Voccio, 한승용 (Seungyong Hahn), Youngjae Kim, Jung-Bin Song, Juan Bascuñán, Y. Iwasa

연구주제

Superconducting Materials and Applications · Superconductivity in MgB2 and Alloys · Particle accelerators and beam dynamics

NTIS 과학기술표준분류

에너지/자원만에너지·환경·원자력 확장

전기/전자 > 중전기기 > 초전도 기술/제품에너지 외

배정 근거: AI 키워드가 잡은 NTIS 과제의 분류(정책 연계 맵과 같은 방법).

AI 연구 키워드·방법

MgB2 초전도 자석 MRI 자석 영구전류 스위치(PCS) 초전도 접합

극저온 시험

키워드 (OpenAlex)

MRI magnets persistent current switch superconducting joints high-temperature superconductors

초록

This paper presents construction and persistentmode operation results of MgB2coils for a 0.5-T/240-mm cold bore MRI magnet, wind-and-react with monofilament MgB2wire at the MIT Francis Bitter Magnet Laboratory. The magnet, of respective inner and outer diameters of 276 and 290 mm and a total height of 460 mm, has center field of 0.5 T and current density of !! kA/cm2. To limit the continuous length of Hyper Tech supplied MgB2monofilament wire to ≤ 300 m, the magnet was divided into eight series-connected coils, each equipped with a persistent current switch and a superconducting joint. We have manufactured three coil modules. Before being tested as an assembly, each coil was tested individually to ensure its capacity to carry 100-A superconducting current in the range of !0-!5 K. The three coils were then assembled, connected in series, and operated as a 3-coil assembly in persistent mod…

이 논문을 지원한 국가R&D 과제 (NTIS 성과)

NTIS 성과DB(2020–24)에서 DOI 매칭 없음

인접 그래프

노드 hover = 이웃 강조 · 1회 클릭 = 고정 · 고정된 노드 다시 클릭 = 페이지 이동

이 문서와 연결된 페이지

교수 1

한승용

연구주제 1

Superconducting Materials and Applications

정책분야 1

중전기기

키워드 4

초전도 접합 · MRI 자석 · 영구전류 스위치(PCS) · MgB2 초전도 자석

방법 1

극저온 시험